-C Air Controls (Filter, regulator, gage, shut-off) |
1/2 NPT |
| |
-CP Air Controls with precision regulator |
1/2 NPT |
| |
-CO Air Controls with recycle button |
1/2 NPT |
| |
-CPO Air Controls with precision regulator and recycle
button |
1/2 NPT |
| BOTTOM
INLET (designate "B" before ratio dash number,
"BR" on -B10, -B15, -B22 and -B32) 1-1/2 and
2HP pumps (not applicable to high output, chemical, 2.2
HP, or AWD series pumps). |
| 16821
|
Low
air pressure control feature -for operating at air pressures
as low as 3 to 4 psi (0.2 -0.3 bar) |
| 16831
|
Low
temperature modification for special sealing in air drive
for operating temperatures from as low as -20 degrees
F up to normal + 120 degrees F |
| 16834
|
Exhaust
adapter with back pressure balance piston |
| 17860
|
Electrical
stroke counter provision (Includes BZE6-2RQ micro switch)
|
| 25721
|
Mechanical
stroke counter - Installed (6 digit) |
| 27964
|
Interconnecting
inlet - Outlet tubing -1/2" female for 4:1 ratio
series pumps (ATV-4 or DTV-4) |
| 28000
|
Threaded
vent (or purge) ports on standard distance piece except
1.5:1 ratio |
| 28003
|
Test
port - Provides access port in pumps body between inlet
and outlet check valves for 1.5 and 2 HP pumps, -10 ratio
or higher, single acting |
| 28881
|
Air
pilot modification - 1/8 NPT Allows remote start/stop
of pump |
| 29376
|
Three
way cycling spool - for 1.5 and 2 HP single acting pumps
|
| 29702
|
Single
stroke modification |
| 29806
|
Double
distance piece - for 1.5 and 2 HP pumps only, except 1.5:1
ratio |
| 51050
|
Extreme
service cycling modification (Not recommended for long
stall periods) |
| 51331
|
EPR
(Ethylene Propylene) Static seals in wetted section. Applies
to distance piece pumps only. |
| 51345
|
Sour
gas drive provision to N.A.C.E. specifications 1.5 thru
2.2 HP distance piece pumps only, Single air head, Double
air head. |
| 53925
|
Severe
arctic low temperature service. -25, -35, -60, -100, -150,
-151, -225, -300, -450 ratios |
| 55305
|
Tube
ports (5/8 SAE) inlet and outlet - for 1.5 thru 2 HP pumps
15 pump minimum. |
| 55630
|
Stainless
steel (AISI-316) distance piece - for 1.5 thru 2 HP pumps
|
| 51056
|
Exhaust
/ pilot vent combiner |
| 52788
|
Viton
seals - air drive only - 1.5 thru 2.2 HP |
| 54885
|
Rotate
pump body 90 degrees from standard |
| 55516
|
Polyurethane
("W" seal) in "F"or "TV"
series pumps - except high output models |
| 59353
|
Noise
reduction kit. (Fitted). Not available on AFD, DFD, ASFD
& DSFD. |
Note: Not all modifications can be combined or used together.
Consult your Haskel Australia representative when requiring
more than one modification.