Level Control Switches
Key
Features
Series
Series
L471/L471 SC (Electric)
Application:
Used as a high & low level control,
the L471 & L471SC can activate
alarms, provide a switch input for
control systems, or perform a variety
of desired electrical switch operations
actuated by a liquid or liquid interface.
Operation:
As the float is moved by varying liquid
height, a magnet is moved closer
to or further away from a switch enclosure.
As the magnet moves closer, a
reed switch in the enclosure closes.
As the magnet moves further away, the
switch opens. The arm containing the
magnet also acts as a counterweight
for the float.
The float is small and will operate in
liquids with a specific gravity as low as
0.4. The interface type will operate with
a specific gravity differential as low as
0.1. This small float permits an economical
installation in locations where
other controls would be cost prohibitive.

Available with a relay mounted in
an explosion-proof case allowing the
control of larger electrical loads. The
manual override option allows the
operator to manually move the float
arm to the test switch position.
-
Easy to Repair
Repairs on-site in 20 minutes
Quick-Change switch cartridge
- Easy to Field Test
The Manual Override option enables
mechanical and electrical function testing
while installed
- No Leaks
Environmentally-isolated design
operational fluids away from electrical
circuitry
- Lower Operating Costs
Quick-Change, inexpensive replacement
- Lower Inventory
One L471 inverts for both High
level applications
- Versatile
One L471 provides both normally
and normally closed switching by
inverting the L471
- Safe
Certified as explosion-proof 1 for Hazardous
Locations: Class I, Div. 1, Groups B, C, D; Class II, Div. 1,
Groups and Class III, Div.1, by CSA a Nationally
recognized Testing Laboratory
and Canada
- Corrosion Resistant
Standard 316 Stainless Steel wetted
housing components for corrosion
resistance
- Monel, Kynar, Teflon, Teflon Coated,
Hastelloy C, PVC, Polypropylene,
Alloy 20
- Reliable
Sealed switch cartridge prevents
dust, fluids, and corrosion from
interfering with electrical circuity
- Hi & Low Pressure Applications
Available with Stainless Steel
Polypropylene displacer options
various process pressures
|
Series LV471, L971
LV471 Application:
These controls are used as a high or
low level control to sound alarms, operate
control equipment or perform a variety
of desired electrical functions. These
controls will operate in any specific gravity
of 0.7 or higher. The standard unit has
a 3" O.D. sphere float and is rated at 250
psi. The standard float arm is 4" long.
Various floats and float arm lengths are
available to fit your application. These
controls are available with a normally
closed or normally open switch arrangement. This unit is installed
through a 1-1/2" NPT fitting
and the float is attached with a cotter key after the body is screwed
into
place. Various flanged models are also
available to meet your specifications.
L971 Extended, Horizontal Body
Application:
These controls are used as a high
or low level control. The electrical
switch closure may be used to sound
alarms, operate control equipment or
perform any desired electrical function.
These standard units are installed
through a 1" NPT fitting. The standard
float is a solid, high-density polypropylene
material and will operate in specific
gravities of 0.6 or higher. Due to
the length of the float, these controls
must have 3" of vertical clearance for
the unit to operate. This control is available
in a wide variety of designs to
meet any specific requirements.

- Easy to Repair
Repairs on-site in 20 minutes with the
Quick-Change switch cartridge
- No Leaks
Environmentally-isolated design keeps
operational fluids away from electrical
circuitry
- Lower Operating Costs
Quick-Change, inexpensive replacement
parts
- Lower Inventory
LV471 and L971 serve both High& Low level applications
- Versatile
Optional with the LV471 is the choice of
normally open or normally closed switch
positions
- One L971 Provides both normally open,
and normally closed switching by simply
inverting the L971's position
- Safe
Certified as explosion-proof1 for Hazardous
Locations: Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; and Class III, Div.1,
by CSA a Nationally Recognized Testing
Laboratory in the U.S. and Canada
- Corrosion Resistant
Standard 316 Stainless Steel wetted and
housing components for corrosion resis
tance
- Optional Corrosion Resistant Materials
Monel, Teflon Coated, Hastelloy C, and
Alloy 20
- Reliable
Sealed switch cartridge prevents dust,
fluids, and corrosion from interfering
with electrical circuity
- Hi & Low Pressure Applications
Available with Stainless Steel and
Polypropylene displacer options for
various process pressures
|
Series L282/L282CS (Pneumatic)
Easy to Repair
Repair on-site in 20 minutes
with the Quick-change pneu
matic cartridge
Easy to
- Field Test
The manual override option
enables mechanical and
pneumatic function testing
while installed.
- No Leaks
Environmentally isolated design
keeps operational fluid away
from supply gas.
Lower Operating Cost
Quick-change replacement
parts.
Non-bleed output saves gas.
- Lower Inventory
Direct or indirect acting by
changing the supply and
exhaust ports.
Use one 282 on either high or
low level activation
- Safe
Pneumatically activation in an
environmentally-isolated design
- Corrosion Resistant
Standard 316 Stainless Steel
wetted parts for corrosion
resistance.
- Optional Corrosion Resistant
Materials
Monel, Kynar, Teflon, Teflon
Coated, Hastelloy C, PVC,
Polypropylene, and Alloy 20
optional Corrosion Resistant
Materials available.
- Hi & Low Pressure
Applications
Available with Stainless Steel
and Polypropylene displacer
options for various pressures.
|
Series PT265/265SC, PT966
-
Easy to Repair
Repairs on-site in 20 minutes
- No Leaks
Environmentally-isolated design
eliminates the need for seals, torque
tubes, diaphragms, and springs;
keeps operational fluids away from
supply gas
- Lower Operating Costs
Quick-Change replacement parts
- Versatile
Direct or indirect acting by inverting
the PT265 and the PT966
- Lower Inventory
Both the PT265 and PT966 can be
used on either high or low level
activation
- Safe
Pneumatic activation in an environmentally-
isolated design
- Corrosion Resistant
Standard 316 Stainless Steel
wetted and housing components for
corrosion resistance
- Optional Corrosion Resistant Materials
Monel, Teflon Coated,
Hastelloy C, and Alloy 20
- High & Low Pressure Applications
Available with Stainless
Steel and Polypropylene displacer options for
various process pressures
|
Series 102 
Application:
These are used as a level control or
as a high or low level alarm. The pneumatic
output can be used to throttle
valves, sound alarms or perform any
desired pneumatic function. Any liquid
or liquid interface can be monitored.
Operation:
A spring acts as a counterbalance
on the displacer. It is externally
adjustable for various specific gravities.
As the liquid rises, the displacer
and arm assembly is raised, rotating
the trunnion. This action turns the
pilot lever containing an adjustment
screw. This screw operates the pilot
to give the output signal. Output is nonbleed
and is either throttling or snapacting.
All adjustments are factory set
and are field adjustable.
- Large Pass-Through Volume
Large orifice size permits higher
pass through volumes for activating
large control valves
- Field Adjustable
For various specific gravities and
output points
- Lower Operating Costs
Optional Non-Bleed output saves
gas
- Reliable
Self-Lubricating packing increases
product life
- Easy Pressure Verification
Pressure gauges on both the
supply and output ports
- Versatile
Available with Snap or Throttling
action, and a horizontal or vertical
displacer
- High & Low Pressure Applications
PVC displacer, and other
optional displacers, work in both high and
low process pressures
- High Temperature Applications
TFE or Stainless Steel displacers
work in high temperature
processes
|
Series 700 & 35 
LINC-700 Series External Cage
These cages are used with the
LINC-L471 electric, LINC-PT265
and LINC-282 Series pneumatic
level controls. Available with or without
the LINC 35-Series sight glass.
The process connection is a standard
1" NPT. Available in other
sizes and options.
- Of level and control operation with
Optional bull's-eye sight glass
- Optional External Cage allows field
servicing without tank drain-down
- Standard cast Ductile in the 1" & 1 1/2" NPT
cage body, and cast Steel in the Ring Bolted cage body
- 316 Stainless Steel, consult factory for
other optional materials
LINC-35
Series Sight Glass
The 35 Series is a bull's-eye sight
glass with either a 1 1/2" NPT or 2" NPT.
These can be used at the same level as the pneumatic or
electrical level controls to show visual
liquid level over a small range.
They can also be used in conjunction
with the external cages to provide
visual indication on level controls
or safety systems.
- Of level and control operation
- Available with a PyrexTM glass lens
- Standard 303 Stainless Steel
- 316 Stainless Steel, consult factory for other optional
materials
|
Series
NF265/NF282
Application:
These flow indicators are
used to monitor flow/no flow.
The electric or pneumatic output
is used to alarm, operate
valves, control pumps or perform
any desired electrical or
pneumatic function.
Operation:
A flowing fluid moves the paddle
activating an electric switch or
pneumatic output.
- Easy to Repair
Repairs on-site in 20 minutes
with the Quick-Change cartridge
- No Leaks
Environmentally-isolated
design keeps operational
fluids away from electrical
circuitry and supply gas
- Lower Operating Costs
Quick-Change, inexpensive
replacement parts
- Non-Bleed output saves gas
-
Lower Inventory
Pneumatic NF282 provides
direct or indirect acting by
changing the supply and
exhaust ports
- Bi-directional flow through rotating
the Electric NF265
- Safe
Pneumatic activation in an
environmentally-isolated design
- NF265 certified as explosionproof
1 for Hazardous Locations:
Class I, Div. 1, Groups A, B, C,
D; Class II, Div. 1, Groups E, F,
G; and Class III, Div.1, by CSA
a Nationally Recognized Testing
Laboratory in the U.S. and
Canada
- Reliable
Sealed switch cartridge prevents
dust, fluids, and corrosion
from interfering with electrical
circuity
- Corrosion Resistant
Standard 316 Stainless Steel
wetted and housing components
for corrosion resistance
- Optional Corrosion Resistant Materials
Monel, Kynar, Teflon, Teflon
Coated, Hastelloy C, PVC,
Polypropylene, and Alloy 20
|
Series FV 3064
Application
These flow indicators are
used to monitor flow/no flow
and have a sensitivity as low as 1.5 oz. of water/minute.
Chemical injectors, glycol
pumps and other low flow applications
are indicated by a
switch closure. The standard
model indicates flow at 0.45
GPM and no-flow at 0.30 GPM.
Operation
As flow enters the inlet, the slug
containing a magnet is raised.
This action actuates the single
pole, double-throw switch in the
enclosure. There is no mechanical
linkage between the slug and
the switch; a magnetic field does
the work. When flow decreases,
the slug drops and the switch
moves to the opposite pole.
- Easy to Repair
Repairs on-site in 20 minutes
with the Quick-Change switch
cartridge
- No Leaks
Environmentally-isolated
design keeps operational fluids
away from electrical circuitry
- Reliable
Sealed switch cartridge prevents
dust, fluids, and corrosion
from interfering with electrical
circuity
- Lower Operating Costs
Quick-Change, inexpensive
replacement parts
- Lower Inventory
Mounts vertically or horizontally
through rotating the installation
of the FV3064
- Excellent Low-Flow
Performance
Optional sensitivity ratings avail
able as low as 1.5 oz./minute
- Durable
Standard cast brass construction
- Optional Corrosion
Resistant Materials
316 Stainless
Steel
- High & Low Pressure Applications
Working pressures up to 1,500 psi
|
Operating Guidelines
| Series |
Downlaod info (PDF) |
| L471, L471 SC, LV471, L971 |
|
| Series 282/282CS |
|
Download
Catalogue
|
 |